Immunity
-
ICIM EFT
Measuring service IC Immunity Measurement Line Conducted acc. IEC 62215-3
The ICIM EFT measurement service measures the immunity of an IC to standardized conducted transient electrical disturbances according to IEC 62215-3. The disturbances, generated by an EFT/burst generator according to standard IEC 61000-4-4, which are not necessarily matched to the operation of the d…
-
ICIM ESD
Measuring service IC Immunity Measurement Line Conducted acc. IEC 61000-4-2 (HMM)
The ICIM ESD measurement service is an ESD test based on current requirements of the regular component specification, which defines a test of the IC with an ESD test gun according to ISO 10605 for global pins (ESD on system level). For the ESD test gun, 150 pF and 330 Ω are specified as the discharg…
-
ICIM Field
Measuring service IC Immunity Measurement Field Coupled Analysis
The ICIM Field measurement service consists of tests of the conducted interference coupling, in which the respective near fields (RF, ESD, burst) are coupled into the test IC in function by means of separate magnetic and E-field sources. It is a further investigation to the tests according to IEC 62…
-
ICIM L-EFT
Measuring service IC Immunity Measurement Conductive Coupling Langer EFT Pulses
The ICIM L-EFT measurement service determines the pulse immunity of ICs using the P202 and P302 pulse generators. During a burst/ESD device test, the generated pulse-shaped disturbances reach the ICs used in the device under test. To test these ICs individually, the pulse generators replicate the at…
-
ICIM SL
Measurement Service for IC Immunity with Stripline acc. to IEC 62132-8
The ICIM SL measurement service determines the immunity of an IC to high-frequency radiated electromagnetic emission in the frequency range from 150 kHz to 3 GHz in accordance with the IEC 62132-8 standard. The test IC is mounted on an IC measurement adapter printed circuit board (PCB), which is loc…
-
ICIM TEM
Measurement service IC Immunity Measurement TEM Cell Method acc. IEC 62132-2
The ICIM TEM measurement service determines the immunity of an IC to high-frequency radiated emission in the frequency range from 150 kHz to 1 GHz in accordance with the IEC 62132-2 standard. The test IC is mounted on an IC measurement adapter printed circuit board (PCB), which is fixed in a suitabl…