ICI 01 L-EFT set
IC EM Pulse Injection Langer Pulse
Short description
The ICI 01 L-EFT set includes one of our ICI L-EFT sources. The sources couple fast transient pulses into test ICs.
You can choose between electric, magnetic, and current sources.
All sources allow for side channel analysis or testing the immunity of individual areas of ICs.
Scope of delivery
- 1x ICI Field Source, Choose your probes from our selection
- 1x BPS 202, Burst Power Station
- 1x BPS 202-Client, BPS 202-Client Software / USB
- 1x NT Ex EU, Power Supply Unit
- 1x ICI 01 L-EFT acc, Accessories
- 1x ICI case, System Case
- 1x ICI m, ICI Set User Manual
Technical parameters
Pulse parameter | |
Rise time | < 2 ns |
Repetition frequency | 0.1 Hz - 20 kHz |
Polarity (set by software) | + / - / alternating |
Trigger-pulse delay (Bypass Mode - Delay Line) | |
min. Trigger-pulse delay (typ.) | 100 ns |
max. Trigger-pulse delay (typ.) | 450 ns |
max. Jitter (typ.) | ± 1 ns |
Trigger-pulse delay (Timer Mode) | |
min. Trigger-pulse delay (typ.) | 200 ns |
max. Trigger-pulse delay (typ.) | 100 ms |
max. Jitter (typ.) | ± 15 ns |
Trigger delay, min. increment | 10 ns |
Supply voltage | BPS 202 |
Software | BPS 202-Client / DLL (32 Bit / 64 Bit) Win XP SP3 or higher |
Scope of delivery details
-
ICI Field Source
Choose your probes from our selection
Choose one of our ICI field sources for either the ICI 01 set.
-
BPS 202
Burst Power Station
The BPS 202 is used as power supply and control unit for the Langer EMV-Technik GmbH pulse probes. The control unit is connected to the user PC via an USB interface. BPS 202-Client software does the controlling. With the BPS 202 input "sync" interference pulses of the connected probes can be synchro…
-
BPS 202-Client
BPS 202-Client Software / USB
The BPS 202-Client software is used to control the BPS 202 Burst Power Station and thereby the connected probe. The software is installed on the user PC.